• Trang Chủ | Sản phẩm

Products

We Are The Best In The Industry

1-Phase Surge Protection Device 50kA/phase

  • Single-phase surge protection device, 50kA/phase.
  • Measured Limiting Voltage (MLV): 760V (L-N) @ A3 Ring Wave 6kV, 200A, suitable for protecting sensitive electrical equipment, electronic devices, and control systems.

Product code: TK-PK050R-1P240-L

Origin: Made in U.S.A

Guarantee: 3-Year Unlimited Free Replacement

Category:

Policy & Commitment

3-year warranty
24/7 technical support
Free technical consultation and installation
Nationwide delivery
Product description

The PanelTrack-R Single-phase surge protection device is a Type 1 SPD certified to UL 1449 standards, capable of handling a maximum surge current of up to 5kA/phase. It is ideally suited for protecting service entrance and branch panel applications.

PanelTrack-R provides reliable protection against transient overvoltages caused by direct lightning strikes on power lines as well as electrical disturbances from the utility grid.

Key Features of the PanelTrack-R Surge Protection Device:

  • Certified to UL 1449 Type 1 standard.
  • Maximum rated surge current (Imax): 50kA/phase.
  • Measured Limiting Voltage (MLV): 760V (L-N) @ 6kV, 200A.
  • Response Time: < 1 nanosecond.
  • Short-Circuit Current Rating (SCCR): 200kAIC.

The PanelTrack-R surge protection device is equipped with integrated Component Level Fusing (CLF), allowing direct installation into the electrical system without the need for a separate disconnect device, while still ensuring maximum safety for the electrical system during operation.

APPLICATIONS:

  • Compliant with ANSI/IEEE C62.41 Categories C, B, and A.
  • Suitable for protecting service entrance and branch panel applications.
  • Effective against high-energy lightning surges and common “ring-wave” transients.
  • Compact design allows installation inside electrical panels, minimizing conductor length and significantly reducing residual voltage.

TECHNICAL SPECIFICATIONS:

  • Function: Surge protection and surge suppression.
  • System configuration: 3 Phase, 4 wires + Ground.
  • System voltage: 240VAC.
  • Device type: Type 1 according to UL 1449.
  • Connection: Parallel installation with the electrical system.
  • Maximum Continuous Operating Voltage (MCOV): 320V (L-N; N-G).
  • Maximum Rated Surge Current (Imax): 50kA/phase.
  • Integrated Component Level Fusing (CLF).
  • Protection Modes: All modes (L-N, N-G).
  • Response Time: < 1 nanosecond.
  • Measured Limiting Voltage (MLV): 760V (L-N) (A3 Ring Wave 6kV, 200A).
  • Short Circuit Current Rating (SCCR): 100kAIC.
  • Status indicator lights.
  • Operating Environment: -40°C to 70°C; 5% to 95% non-condensing humidity.
  • Vỏ bọc: NEMA 4X
  • Tiêu chuẩn: UL 1449 4th Ed., Type 1 SPD for Type1 & Type 2locations; ANSI/IEEE C62.41 & C62.45.